Descriptions :GXOS / E - 1236 - Series Class I termination kits are Heat Shrinkable terminations kits designed for Single Core extrued dielectric, shielded, armoured & unarmoured cables upto 36kV rated voltage.
|
|
| |
BILL OF MATERIAL STD.
PACKING KIT ( + ) |
 |
Cable Components |
 |
Kit Components |
 |
Installation aids & Accessories
(Part of std. kits) |
|
 |
Cable Components |
| No |
Descriptions |
| 2. |
Conductor |
| 14. |
Outer Sheath |
| 15. |
XLPE Insulation |
| 16. |
Armour |
| 17. |
Metal Shied |
| 18. |
Semi-Conducting Screen |
|
|
|
| |
 |
Kit Components |
|
| No |
Descriptions |
Qty . |
| 1. |
Terminal Lug |
1 No. |
| 3. |
Heat Shrinkable Adhesive Lined Terminal Sleeve |
1 No |
| 4. |
Lug Sealing Tape/Mastic Strip |
1 Strips. |
| 5. |
Rain Sheds |
|
| |
12 KV System |
2 Nos. |
| |
24 KV System |
3 Nos. |
| |
36 KV System |
4 Nos. |
| 6. |
Anti Tracking Sleeve |
1 No. |
| 7. |
Stress Control Sleeve |
1 No. |
| 8. |
Stress Control Mastic |
1 Strips. |
| 9. |
Constant Force Spring Roll (Alternatively Solder Tack) |
1 No. |
| 10. |
Copper Braid for Screen Earthing |
1 No. |
| 11. |
Worm Drive Clip |
1 No. |
| 12. |
Adhesive Lined Gland Sleeve (only for armoured cables) |
1 No. |
| 13. |
Tinned Copper Braid duly fitted with Terminal Lug at One end + Solder block |
6 No. |
|
|
| |
 |
Installation aids & Accessories (Part of std. Kits) |
|
| No |
Descriptions |
Qty . |
| 1. |
Mastic Sealing Tape |
1 Roll. |
| 2. |
Silicone Grease |
1 No. |
| 3. |
Cleaning Tissue |
2 Nos. |
| 4. |
Nylong String for Cutting XLPE Insulation |
1 No. |
| 5. |
Aloxite Emery Tape |
3 Pc. |
| 6. |
Mopping Cloth |
1 Pc. |
| 7. |
Installation Instruction Manual |
1 No. |
|
|
| |
| Electrical Performance (12 kV Rated Accessories) |
| Tests |
12 kv System
(6.6/6.6 KV,6.35/11KV) |
15-24kV System
(8.7/15KV,11/11KV,12.7/22KV) |
36kV (19/33KV) |
|
A.C. Dry Withstand 1 Minute |
35KV/1 minute |
50KV/1 Minute |
75KV/1 Minute |
|
D.C. Withstand 30 Minute |
48 KV |
96 KV |
144 KV |
| Lightening Impulse withstand Voltage |
75 KV |
125 KV |
170 KV |
| Partial Discharge |
12.7 Kv < 5 Pc |
25 Kv < 5 Pc |
38 Kv < 5 Pc |
|
|
| |
Accessories and optional items
- Standard Tail Length is 900, 800 & 600mm for outdoor and 700, 550, 450mm for indoor termination for 36Kv, 24Kv & 12Kv respectively.
- Solderless and special purpose earthing kits also available on request.
- Polymeric Insulators and T Brackets for installation of terminations on single pole are available on request.
Note
- All kits are supplied with full kit contents for making a termination.
- Rain sheds for indoor termination 12 kV - No Rain shed, 15 -24 kV - 1 No. Rain shed, 36 kV - 2 Nos. Rain sheds.
|
|
| |
| Ordering Informations |
| 12 KV System |
15 - 24 KV System |
36 KV System |
Cable size
(sq. mm) |
Kit Code |
Cable size (sq. mm) |
Kit Code |
Cable size
(sq. mm) |
Kit Code |
| |
Indoor |
Outdoor |
|
Indoor |
Outdoor |
|
Indoor |
Outdoor |
| 16-50 |
GXES-11 |
GXOS-11 |
16-50 |
GXES-21 |
GXOS-21 |
25-50 |
GXES-31 |
GXSS-31 |
| 70-120 |
GXES-12 |
GXOS-12 |
70-120 |
GXES-22 |
GXOS-22 |
70-185 |
GXES-32 |
GXSS-32 |
| 150-300 |
GXES-13 |
GXOS-13 |
185-300 |
GXES-23 |
GXOS-23 |
240-500 |
GXES-33 |
GXSS-33 |
| 400-630 |
GXES-14 |
GXOS-14 |
400-630 |
GXES-24 |
GXOS-24 |
630-800 |
GXES-34 |
GXSS-34 |
| 800-1000 |
GXES-15 |
GXOS-15 |
800-1000 |
GXES-25 |
GXOS-25 |
1000 |
GXES-35 |
GXSS-35 |
|
|